Nanjing,China
+86-13813931455(WhatsApp)
sales@hiclover.com

Tag: Hospital-Incinerators

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

Kinds of waste Generated in the health facility

HICLOVER Incinerator/Parts Range Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Ranked for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other creature incineration Temperature Control, Primary and Secondary Stoking tools Stainless Steel Spark Screen Primary Chamber Door Locking System HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification. 1. Medical Waste Incinerator(Containerized…
Read more

Poultry Incinerator Design for Pets Cremation Business

Model A1500 Picture   Brand/Product Code HICLOVER/N1134 Burning Rate Typical 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Fuel Type Diesel Oil/ Organic Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Typical 34 kg/hour…
Read more

Garbage Incinerator TS150 PLC Mobile Type

Items/Model HICLOVER TS150(PLC) (Mobile Sort ) N1155 Picture  mobile incinerator Principle Waste Incineration Remedy,trash incinerator Burn Rate Average 150 kg/hour Feed Capacity Average 150kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Electricity 0.9Kw Oil Infection (kg/hour) average 20.4 Gas Consumption…
Read more

Medical Waste Management System

Items/Model TS50(PLC) Picture Principle Medical Waste Incineration  Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Gas Flue Washing System incineration of medical waste Feed Mode Manual Voltage 220V Power 4.0 Kw Oil Infection (kg/hour) Typical 16.9 Gas Consumption (m3/hour) Typical 20.2 Infection Monitor…
Read more

Incinerator for Waste Management Facility and Spare Parts

Items/Model TS500(PLC) Picture   Principle Waste Incineration Treatment Burn Rate Average 500 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700Liters (2.7m3) Internal Dimensions 190x120x120cm Secondary Chamber 1300Liters (1.3m3) Smoke Filter Chamber Dry Scrubber Chamber Feed Mode Manual Voltage 220V Electricity 3.0Kw Oil Consumption (kg/hour) Typical 44(DO) Gas Consumption (m3n/hour) Typical 53(NG) Infection Monitor Digital…
Read more

Guidelines on waste management Incinerator Model YD-20C

Item Specification Model YD-20C Main Product List   Main Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(Update to Stainless Steel, free cost) Italy Petroleum burner: 02 sets Oil Tank: 100Liters   Optional: Mobile Trailer for Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Mobile Type Incinerator Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion…
Read more

MEDICAL WASTE INCINERATOR

Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. 1. Incinerator 10kg per hr 2. Incinerator 20kg per hr 3. Incinerator 50kg per hr 4. Incinerator 100kg per hr 5. INDOOR INCINERATOR 2021-02-23 Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other creature incineration medical waste disposal methods Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn…
Read more

What are the key products of incineration process

Items/Model TS800 Picture   Principle Animal Waste Incineration Treatment Burn Rate Average 300-450 kg/hour Feed Capacity Average 1200kg/feeding Control Mode Electric Control Combustion Chamber 3000Liter Internal Dimensions 300*100*100 cm Secondary Chamber *** Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) ***waste to Power plants cost Gas Consumption (m3/hour) Ave.22.8m3n/hr Temperature Monitor Digital Display Temperature Protection Yes…
Read more

Steps of waste management

Item Specification Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – yes Cow – Little Main Product List Main Combustion Chamber   Secondary Combustion Chamber   Mix-Combustion Chamber   Wet Scrubber( Washing Tower)   Incinerator Control Case   Chimney:10.0Meters *(Update to Stainless Steel, free Price )  …
Read more

What is medical waste management

Item Specification Model YD-20C Main Product List   Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free Price ) Italy oil burner: 02 sets Oil Tank: 100Liters   Optional: Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Mobile Trailer for Incinerator Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. bio medical waste management ppt 2020 HICLOVER Incinerator/Parts Range Main Feature…
Read more