Incinerator with Capacity of destruction in weight: 60 Kg/h.

Capacity of destruction in weight: 60 Kg/h. It should be able to operate not less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification : Types A, B, C, D, and E of medical waste  “PYROLYTIC” combustion, by controlling the gasification of…
Read more

Incinerator with Capacity of destruction in weight: 60 Kg/h.

Capacity of destruction in weight: 60 Kg/h. It should be able to operate not less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification : Types A, B, C, D, and E of medical waste  “PYROLYTIC” combustion, by controlling the gasification of…
Read more

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber     Temperature Monitoring Yes     Average ash residue (%) 3%     Thermostatic Device Yes   1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber     Temperature Monitoring Yes     Average ash residue (%) 3%     Thermostatic Device Yes   1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Refractory constructions incinerator

* Burning Rate                                                     (50-120kg/hour) * Minimum Operating Temperature                (850°ϲ(Primary combustion) * Maximum Operating Temperature               (1450°ϲ(Afterburner chamber) * Secondary Burning Capacity                         (Compulsory) * Density Insulation                                           (20mm high) * Refractory Casting                                          (Minimum 65mm) * Heavy duty refracting lining to withstand    (1500°ϲ) * Average burn out time: Maximum                (3.0 hours) * Fuel Type                                                          (Diesel) * Fuel Consumption in L/hr:                            (7.5 to 9) * Residence time in secondary chamber     (2 sec.) * Residue ash post 100kg                               (Max. 3.8kg) * Installation period                                            (Maximum 7days) Type : Refractory constructions Steel Structure 400+ Silica board + Fire Brick and Castable between Size : Outside – W 740 x L 1112 x H 790 / Inside – W 400 x L 800 x H 560 (mm) Fire load of Combustion volume : 0.18 m3 Fire table area : 0.32 m2 Material : SS400 x 6.0T, Silica Board, Fire Brick (SK-36), Castable (HACT-160) Temperature : 700 ~ 900 ℃ Residual gas combustion in secondary chambers : ≥ 2sec Input door size : W 200 x H 200 (mm) Ash door size : W 300 x H 400 (mm) Type : Refractory constructions Steel Structure 400+ Silica board + Fire Brick and Castable between Size : Outside – W 740 x L 1112 x H 745 / Inside – W 400 x L 800 x H 600 (mm)   Fire load of Combustion volume : 0.19 m3   Fire table area : 0.32 m2 Material :  SS400 x 6.0T, Silica Board 50T, Fire Brick (SK-36), Castable (HACT-160) Temperature : 1000 ~ 1100 ℃ WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com   Email: sales@hiclover.com Email: hicloversales@gmail.com   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour…
Read more

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 sets oil burner, batch load  incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber.…
Read more

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital  average 10kgs per hour.  with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Average 20 kgs per feed Burning Rate Average 10 kgs per hour Burning Time per Feed 2 hours Voltage 220V Fuel Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 5.4-12.6 Kgs/Hour…
Read more

Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door

Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – small Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:10.0Meters *(upgrade to…
Read more

Top Feeding Door Solid Waste Incinerators HICLOVER

HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or  3 sections) Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: sales@hiclover.com Email: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter…
Read more

Pre-assembled containerized type waste incinerator

Pre-assembled, containerized type  Burning rate: 100 – 120kg / hour medical waste incinerator  Minimum operating temperature: 8500c   (Primary combustion) Maximum operating temperature: 14500c  (afterburner chamber) Secondary Burning capacity: Compulsory. Density insulation: 20 mm high hospital waste incinerators Refractory casting: minimum 65mm Heavy duty refracting lining to withstand 15000c Average burn out time: maximum 3.0 hrs Fuel…
Read more