Municipal waste incinerator

General waste incinerator – Medium Minimum Requirements: General waste incinerator Dual chamber -Medium General requirements,how to neutralize acidity in garbage incinerated waste ” Size and efficiency The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnectionsThe operator will proceed to undertake the following duties: • Initial supervision of the operation of each type of incinerator on a full-time basis for 5 working days, observing and recording each unit’s performance.study of effects of medical wastes burns without incenerator Development of an operating protocol for the client’s nominated staff to use whilst operating the unit. • Practical training of the client’s nominated personnel, in the operation and routine maintenance of the unit. • Assessing the volume and types of waste awaiting incineration and developing an operating schedule for the client. • All equipment manuals shall be provided in English and in French.Containerization The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. Warranty period: “Warranty will be as per the UNOPS ‘contracts for the provision of goods’ under section 4.5 of the ‘general conditions of contract’ how much cubic meters of incinerator can burn 600 kg of waste 4.5 WARRANTIES: Unless otherwise specified in the Contract, in addition to and without limiting any other warranties, remedies or rights of UNOPS stated in or arising under the Contract
Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9 Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm Secondary Chamber 600L 750L 1000L 1500L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44 Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes