Nanjing,China
+86-13813931455(WhatsApp)
sales@hiclover.com

Category: What’s New

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.

Industrial hazardous and nonhazardous waste and medical infectious waste

Industrial hazardous and nonhazardous waste and medical infectious waste Incinerator Items/ModelHICLOVER TS500(PLC)HICLOVER TS300(PLC) Burn Rate (Average)500-600 kg/hour300-500 kg/hour Feed Capacity(Average)600kg/feeding400kg/feeding Control ModePLC AutomaticPLC Automatic Primary Combustion Chamber3000Liters(3.0m3)2000Liters(2.0m3) Internal Dimensions2100x1200x1200mm1700x1200x1000mm Secondary Chamber1500Liters(1.5m3)1000Liters(1.0m3) Smoke Filter ChamberYesYes Feed ModeManualManual Type of industries: Food processing units, beverages, Milk processing plants. Incineration per day requirement: 300 to 500 Kg per…
Read more

industrial waste incinerator

Items/Model TS2000 (Top Feeding) Principle Waste Incineration Treatment Burn Rate Average 500-600kg/hour Feed Capacity Average 4500kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 7700Liter (7.7m3) Internal Dimensions 5000*1400*1100 mm Secondary Chamber 4000Liter (4.0m3) Feed Mode Manual/Forklift/Crane DescriptionBrandModelFuel Type Waste IncineratorHICLOVERTS2000Oil/Gas *Primary combustion chamber *Secondary combustion chamber * Stainless Steel chimney *Auto PLC control system…
Read more

Vertical closed incinerator combustion chamber

Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, general wastes. Incinerator Items/ModelHICLOVER YD300(PLC)HICLOVER YD500(PLC) Burn Rate (Average)300-500 kg/hour500-600 kg/hour Feed Capacity(Average)480kg/feeding800kg/feeding Control ModePLC AutomaticPLC Automatic Primary Combustion Chamber2400L(2.4M3)4000L(4.0M3) Internal Dimensions220x110x100cm257x147x108cm Secondary Chamber1200L1500L Smoke Filter ChamberYesYes…
Read more

Waste Incinerator Capacity average 30-50 kgs per hour

Waste Incinerator Capacity average 30-50 kgs per hour ModelYD-30C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case (PLC Auto Type) Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 200Liters Optional: Mobile Trailer for Incinerator Nanjing Clover Medical Technology Co.,Ltd. Ecolead…
Read more

Waste Incinerator HICLOVER TS100

*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc Waste IncineratorHICLOVERTS100 Burn Rate (Average) 100-150 kg/hour Feed Capacity(Average) 200kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 1200Liters(1.2m3) Internal Dimensions 120x100x100cm Secondary…
Read more

Incinerator Items/Model HICLOVER TS20(PLC)

Main Product List per 01 set Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 units Oil Tank (if oil fuel): 200Liters Incinerator Items/Model HICLOVER TS20(PLC) Burn Rate (Average) 20-30 kg/hour Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary Combustion…
Read more

HICLOVER TS300(PLC) PLC Automatic Waste Incinerator

Default: Side Feeding Door Optional: Front/Top Feeding Door, Wet scrubber Incinerator Items/ModelHICLOVER TS300(PLC) Burn Rate (Average)300 kg/hour Feed Capacity(Average)400kg/feeding Control ModePLC Automatic Primary Combustion Chamber2000Liters(2.0m3) Internal Dimensions1700x1200x1000mm Secondary Chamber1000Liters(1.0m3) Nanjing Clover Medical Technology Co.,Ltd. Ecolead Technology(Nanjing) Co.,Ltd. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com 2023-04-09

INDUSTRIAL WASTE INCINERATORS FOR ALL SITES

Picture Feeding Door LocationTop/Side Loading Burn Rate (up to)200-300 kg/hour Control ModePLC Automatic Primary Combustion Chamber2000L(2.0M3) Primary Combustion Chamber Internal Dimensions2000x1200x850mm Secondary Combustion Chamber1000L(1.0m3) Feed ModeManual/forklift/crane ***forklift/crane supply by local We are particularly interested in your range of mobile incinerators and would appreciate it if you could provide us with a detailed quote that includes…
Read more

Medical waste incinerator Burning Rate 100kg/hr

Subject Medical waste incinerator Day Capacity 1000kg Waste Type Medical waste www.hiclover.com/#!/Model-TS100-Medical-Waste-Incinerator-100-150kgs-per-hour-capacity/p/416001748/category=0 DescriptionBrandModelFuel Type Medical IncineratorHICLOVERTS100Diesel Oil/Natural Gas *Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc Incinerator Items/ModelHICLOVER TS100(PLC) Burn…
Read more

Waste Incinerator YD500(PLC) and YD600(PLC)

Thermocouples (S type) Thermocouples Tube(Corundum ) PLC Recording Function 5mm Steel shell Window on feed door Incinerator Items/ModelHICLOVER YD500(PLC)HICLOVER YD600(PLC) Burn Rate (Average)500-600 kg/hour600-800 kg/hour Feed Capacity(Average)800kg/feeding11000kg/feeding Control ModePLC AutomaticPLC Automatic Primary Combustion Chamber4000L(4.0M3)5500L(5.5M3) Internal Dimensions257x147x108cm300x147x125cm Secondary Chamber1500L1500L Smoke Filter ChamberYesYes Feed ModeManualManual Voltage220V220V Power4.8Kw6.0Kw Burner TypeItaly BrandItaly Brand Nanjing Clover Medical Technology Co.,Ltd. Ecolead…
Read more